Our test facility allows us to test all the control functions of the Nirvana system. We use Nirvana Drive Motors to test the output Drive Function.
The Fault code system is excellent however our test procedure allows us to bypass Fault codes that can be misleading. This enables us to see the underlying problems.
We like to see the complete drive as well as the controller.
Test the motor and the Hall Effect sensors before installing the repaired drive.
Please take extreme care in packaging the unit for shipping.
The Nirvana system is an excellent efficient Compressor Drive System.
See Technical Information
Ingersoll Rand Nirvana CCN22156806 MD75TLIR with RED75TL Input Rectifier 220-240 VAC IN SEMIKRON VS Drive Complete
PEF720ND000 Top Control Board
PEF720NE000 Sub Control Board with:
PEF722NF001 ID Board
SEMIKRON IGBT Driver Assembly
LSPPD Thyristor Assembly
CNX999RR002 6 Capacitor Bank
6 - SEMIKRON SKC2M2-40A-1 Capacitors
8.2
0448
RED75TL Input Rectifier Module